Customization: | Available |
---|---|
Warranty: | 5 Years |
Nature of Source Flow: | Other |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
SUN-10K-SG04LP3-EU
|
SUN-12K-SG04LP3-EU
|
Battery Input Data
|
||
Battery Type
|
Lead-acid or Lithium-ion
|
|
Battery Voltage Range (V)
|
40~60V
|
|
Max. Charging Current (A)
|
210A
|
240A
|
Max. Discharging Current (A)
|
210A
|
240A
|
Charging Curve
|
3 Stages / Equalization
|
|
External Temperature Sensor
|
Yes
|
|
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
|
PV String Input Data
|
|
|
Max. DC Input Power (W)
|
13000W
|
15600W
|
Rated PV Input Voltage (V)
|
550V(160V~800V)
|
|
Start-up Voltage (V)
|
160V
|
|
MPPT Range (V)
|
200V-650V
|
|
Full Load DC Voltage Range (V)
|
350-650
|
|
PV Input Current (A)
|
26A+13A
|
|
Number of MPPT / Strings per MPPT
|
2/2+1
|
|
AC Output Data
|
||
Rated AC Output and UPS Power (W)
|
10000W
|
12000W
|
Max. AC Output Power (W)
|
11000W
|
12000W
|
Peak Power (off grid)
|
2 times of rated power, 10 S
|
|
AC Output Rated Current (A)
|
15.2
|
18
|
Max. AC Current (A)
|
22.7
|
27
|
Max. Continuous AC Passthrough (A)
|
45A
|
50A
|
Output Frequency and Voltage
|
50/60Hz;3L/N/PE 220/380Vac,230/400Vac
|
|
Grid Type
|
Three Phase
|
|
Current Harmonic Distortion
|
THDi<3% (Linear load<1.5%)
|
|
Efficiency
|
||
Max. Efficiency
|
97.60%
|
|
Euro Efficiency
|
97.00%
|
|
MPPT Efficiency
|
99.90%
|
|
Protection
|
||
Integrated
|
Anti-islanding Protection, PV String Input Reverse PolarityProtection, Insulation Resistor Detection, ResidualCurrentMonitoring Unit, Output Over Current Protection, Output Shorted Protection
|
|
Surge Protection
|
DC Type III / AC Type III
|
|
Over Voltage Category
|
DC Type II/AC Type III
|